Objective: Evaluate the safety of the technique: Laser-assisted liposuction Diode 980-nm, presenting the rate of complications obtained in our interventions. Methods: A retrospective, descriptive and analytical study was carried out that included ten (10) patients selected with inclusion criteria between the months of January and September 2018, using a 980-nm Diode Laser (SixLáserDuo®) equipment whose energy used was 12 to 15 watts through a 600 μm fiber. Results: The average age of the patients was 29.6 years (range: 18 to 42 years), the complication was the hematoma 10% (1/10 patients) due to omission of medication and ecchymosis by 3% (3/10 patients). Pain control time of 1 to 2 days. Conclusions: The Lipoláser of mons pubis with the Laser Diode 980-nm, is a less traumatic proven technique, without major complications and with a low rate of minor complications reducing the recovery period of patients.
Published on 01/01/2023
Volume Revista Latinoamericana de Ginecología Regenerativa. Volumen 1, número 1, 2023
DOI: https://doi.org/10.5281/zenodo.8196713
Licence: CC BY-NC-SA license
Are you one of the authors of this document?