The present work evaluates the influence of different primers applied in the reinforcement steel on the apparent diffusion coefficient of oxygen and on the corrosion intensity (Icorr), comparing the results with a reference cimentitious mortar. Oxygen flow (J until the reinforcement steel was measured by potenciostático method in steady state. The was monitored by the Polarization Resistance technique (Rp). Evaluations related porosity of the primers were made through magnifying glasses, optical microscopy and SEM. Primers that represent barrier protection systems proved to be less permeable to oxygen. The values ranged from to , causing variation in the due to cathodic control of the corrosion process.
Published on 01/01/2018
DOI: 10.21041/ra.v8i3.336
Licence: CC BY-NC-SA license