Abstract

Purpose

Develop a method for the optimal placement of sensors in order to detect the largest number of contaminant release scenarios with the minimum amount of sensors.

Design/methodology/approach

The method considers the general sensor placement problem. Assuming a given number of sensors, every release scenario leads to a sensor input. The data recorded from all the possible release scenarios at all possible sensor locations allow the identification of the best or optimal sensor locations. Clearly, if only one sensor is to be placed, it should be at the location that recorded the highest number of releases. This argument can be used recursively by removing from further consideration all releases already recorded by sensors previously placed.

Findings

The method developed works well. Examples showing the effect of different wind conditions and release locations demonstrate the effectiveness of the procedure.

Practical implications

The method can be used to design sensor systems for cities, subway stations, stadiums, concert halls, high value residential areas, etc.

Originality/value

The method is general, and can be used with other physics‐based models (puff, mass‐conservation, RANS, etc.). The investigation also shows that first‐principles CFD models have matured sufficiently to be run in a timely manner on PCs, opening the way to optimization based on detailed physics.

Full Document

The PDF file did not load properly or your web browser does not support viewing PDF files. Download directly to your device: Download PDF document
Back to Top

Document information

Published on 01/01/2005

DOI: 10.1108/02644400510588076
Licence: CC BY-NC-SA license

Document Score

0

Views 5
Recommendations 0

Share this document

claim authorship

Are you one of the authors of this document?