Abstract

The existing parallel type pressurized water supply pipeline of high-rise buildings has been improved to build energy-saving high-rise building water supply systems. Series-parallel combined constant pressure water supply pipeline is designed. Antipollution high water tank is reasonably installed above the middle area of the building to supply water for the middle area high water tank and supply pressurized water by water pumps for high-rise district. And PLC control system is designed to control the work efficiency of the water pumps according to the sensor feedback information. Verified by calculation and simulation, series-parallel combined constant pressure water supply pipeline is better than parallel water supply pipes in saving the energy which is about the middle-Hybrid phase consumption of the latter. PLC control is simulated and the results show that PLC can effectively control the water supply system to ensure stable water pressure so as to save energy. Keywordshigh-rise building; water supply pipelines; series-parallel combined; PLC


Original document

The different versions of the original document can be found in:

https://academic.microsoft.com/#/detail/2596489179
https://academic.microsoft.com/#/detail/2031609251
http://dx.doi.org/10.4028/www.scientific.net/amr.760-762.1369


DOIS: 10.2991/iccsee.2013.786 10.4028/www.scientific.net/amr.760-762.1369

Back to Top

Document information

Published on 01/01/2013

Volume 2013, 2013
DOI: 10.2991/iccsee.2013.786
Licence: Other

Document Score

0

Views 1
Recommendations 0

Share this document

claim authorship

Are you one of the authors of this document?