The results of a materials survey for the Baca 50 MW(e) single flash geothermal plant in the Valles Caldera of New Mexico are presented. From the design documents provided, materials proposed for use in contact with the plant atmosphere, the two-phase geofluid, the separated steam, and the recirculating condensate cooling water were assessed for suitability. Special emphasis was given to records of performance of the materials in other geothermal plants. Based upon these considerations of chemical reactivity and plant operating experience, a number of recommendations were made.
The different versions of the original document can be found in:
Published on 01/01/1980
Volume 1980, 1980
DOI: 10.2172/6887185
Licence: CC BY-NC-SA license
Are you one of the authors of this document?