Abstract

Optical Sensing and Detection II, Brussels, Belgium , 16-19 April, 2012 In this paper we present the field testing results of a low-cost all-fibre polarimetric current sensor for the monitoring of current in the European high-speed railway network. The sensor fulfils the requirements of robustness, sensitivity, accuracy and cost required for the monitoring of catenary current in changeover sections. Changeover sections are nonfed sections of the catenary that are placed between sections fed with different phases and that introduce discontinuities in the current collection done by the train. Since the train passes at high-speed between the two sections, an electric arc can be formed that may lead to significant damage of the infrastructure. To avoid this situation, it is essential to ensure the switch-off of the current collection before arriving and switch-on again when the changeover section is passed. An adequate protection system that monitors the current in the catenary before the changeover section allows to trigger the necessary protection mechanisms in the infrastructure. Efficient, robust and lightweight electrical current sensors are therefore essential for this security system. The sensor proposed here uses the Faraday magneto-optic Effect with a well-known polarimetric interrogation method. The optical configuration is extremely simplified through the use of few cost-effective, all-fibre devices with a simplified alignment. It allows high sensitivity for low current values, demonstrating a resolution below the ampere level with a dynamic range up to 500 A. The setup is electronically self-referenced to reduce the effect of small misalignments in the polarization, power variations in the optical source, temperature changes, birefringence effect and bending-induced attenuation in the lead fibre. A set of temperature tests in a climatic chamber were also performed in a range of temperature between -20 up to 80°C, to assess the robustness of the device to operating temperature variations. The field tests include tests during commercial operations and special tests simulating fault conditions.


Original document

The different versions of the original document can be found in:

https://www.spiedigitallibrary.org/conference-proceedings-of-spie/8439/1/Field-testing-of-a-low-cost-self-referenced-all-fibre/10.1117/12.922794.full,
https://ui.adsabs.harvard.edu/abs/2012SPIE.8439E..1TF/abstract,
https://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=1316676,
https://ebuah.uah.es/dspace/handle/10017/26506,
https://academic.microsoft.com/#/detail/2058787565 under the license cc-by-nc-nd
Back to Top

Document information

Published on 01/01/2012

Volume 2012, 2012
DOI: 10.1117/12.922794
Licence: Other

Document Score

0

Views 0
Recommendations 0

Share this document

claim authorship

Are you one of the authors of this document?