International audience; Some direct on-line observer-based approach for leak detection and isolation in pipelines is here presented and tested in simulation. Given indeed a number of possible leaks to be detected, an observer aiming at simultaneous estimation of magnitudes and positions of the leaks is given on the basis of some appropriate model on the one hand, and appropriate excitation on the other hand. The method is illustrated via simulation results.
The different versions of the original document can be found in:
Published on 01/01/2007
Volume 2007, 2007
DOI: 10.23919/ecc.2007.7068535
Licence: CC BY-NC-SA license
Are you one of the authors of this document?