Abstract

The solutions obtained for low Reynolds-number incompressible flows using the same flow solver and solution technique on body-fitted, embedded surface and immersed body grids of similar size are compared. The cases considered are a sphere at and an idealized stented aneurysm. It is found that the solutions using all these techniques converge to the same grid-independent solution. On coarser grids, the effect of higher-order boundary conditions is noticeable. Therefore, if the manual labor required to set up a body-fitted domain is excessive (as is often the case for patient-specific geometries with medical devices), and/or computing resources are plentiful, the embedded surface and immersed body approaches become very attractive options.