Cracks appears in reinforced concrete structures as something inherent to the material they are composed. Causes of diverse kind advise to control this cracking, considering it can not be prevented. The durability of reinforcements is, till now, the reason that has determined, in most structures, the study and the control of this cracking. In this report, the information contained in certain standards in force (CP-110; ACI-318-83; B.A.E.L. 80; MODEL CODE AND EH-82) about the characteristics the concrete must have and about the cracking in pieces of reinforced concrete under pliability attempts, are analysed and resumed, trying to judge later its connection with the corrosion phenomenon in reinforcements.
.La aparición de fisuras en las estructuras de hormigón armado es algo inherente al material de que están compuestas. Razones de índole diversa aconsejan controlar esta fisuración, ya que no puede evitarse. La durabilidad de las armaduras es hasta el momento el motivo que más ha condicionado, para la mayor parte de las estructuras, el estudio y control de dicha fisuración. En esta ponencia se analiza y compendia la información contenida en algunas normativas vigentes (CP-110; ACI-318-83; B.A.E.L. 80; CÓDIGO MODELO YEH-82) sobre las características que debe tener el hormigón y sobre la fisuración en piezas de hormigón armado bajo solicitaciones deflexión, para posteriormente tratar de enjuiciar su relación con el fenómeno de corrosión de las armaduras.
Published on 01/01/2012
DOI: 10.3989/ic.1984.v36.i366.1884