m (Scipediacontent moved page Draft Content 486012726 to Sanders 1982a)
 
Line 3: Line 3:
  
 
Four parameters are used to define a particular pipe: inside diameter, wall thickness, material, and ends. The factors influencing pipe selection are limited to fluid pressure, temperature, chemistry, flow rate, and cost. Other pipe parameters and factors that influence pipe selection and design are mentioned, and, where appropriate, the user is warned that at some stage in the project these factors must be dealt with. It is assumed that the objective is the direct application of geothermal water at temperatures lower than 200/sup 0/F and with 12-in. or smaller pipe. When considering friction losses for sizing purposes, only straight pipe is considered. A discussion of the characteristics and attributes of readily available pipe is included to aid in making a preliminary selection. Energy loss from buried pipe is considered.
 
Four parameters are used to define a particular pipe: inside diameter, wall thickness, material, and ends. The factors influencing pipe selection are limited to fluid pressure, temperature, chemistry, flow rate, and cost. Other pipe parameters and factors that influence pipe selection and design are mentioned, and, where appropriate, the user is warned that at some stage in the project these factors must be dealt with. It is assumed that the objective is the direct application of geothermal water at temperatures lower than 200/sup 0/F and with 12-in. or smaller pipe. When considering friction losses for sizing purposes, only straight pipe is considered. A discussion of the characteristics and attributes of readily available pipe is included to aid in making a preliminary selection. Energy loss from buried pipe is considered.
 
Document type: Report
 
 
== Full document ==
 
<pdf>Media:Draft_Content_486012726-beopen262-6797-document.pdf</pdf>
 
  
  
Line 18: Line 13:
 
* [https://digital.library.unt.edu/ark:/67531/metadc1074228/m2/1/high_res_d/5244377.pdf https://digital.library.unt.edu/ark:/67531/metadc1074228/m2/1/high_res_d/5244377.pdf]
 
* [https://digital.library.unt.edu/ark:/67531/metadc1074228/m2/1/high_res_d/5244377.pdf https://digital.library.unt.edu/ark:/67531/metadc1074228/m2/1/high_res_d/5244377.pdf]
  
* [http://www.osti.gov/geothermal/servlets/purl/5244377-Jdofal/5244377.pdf http://www.osti.gov/geothermal/servlets/purl/5244377-Jdofal/5244377.pdf],[https://www.osti.gov/servlets/purl/5244377 https://www.osti.gov/servlets/purl/5244377],[https://academic.microsoft.com/#/detail/1506641724 https://academic.microsoft.com/#/detail/1506641724]
+
* [http://www.osti.gov/geothermal/servlets/purl/5244377-Jdofal/5244377.pdf http://www.osti.gov/geothermal/servlets/purl/5244377-Jdofal/5244377.pdf],
 +
: [https://www.osti.gov/servlets/purl/5244377 https://www.osti.gov/servlets/purl/5244377],
 +
: [https://academic.microsoft.com/#/detail/1506641724 https://academic.microsoft.com/#/detail/1506641724]

Latest revision as of 11:44, 22 January 2021

Abstract

Four parameters are used to define a particular pipe: inside diameter, wall thickness, material, and ends. The factors influencing pipe selection are limited to fluid pressure, temperature, chemistry, flow rate, and cost. Other pipe parameters and factors that influence pipe selection and design are mentioned, and, where appropriate, the user is warned that at some stage in the project these factors must be dealt with. It is assumed that the objective is the direct application of geothermal water at temperatures lower than 200/sup 0/F and with 12-in. or smaller pipe. When considering friction losses for sizing purposes, only straight pipe is considered. A discussion of the characteristics and attributes of readily available pipe is included to aid in making a preliminary selection. Energy loss from buried pipe is considered.


Original document

The different versions of the original document can be found in:

https://www.osti.gov/servlets/purl/5244377,
https://academic.microsoft.com/#/detail/1506641724
Back to Top

Document information

Published on 01/01/1982

Volume 1982, 1982
DOI: 10.2172/5244377
Licence: CC BY-NC-SA license

Document Score

0

Views 0
Recommendations 0

Share this document

claim authorship