m (Cinmemj moved page Draft Samper 699793772 to Zhang et al 2014c) |
|
(No difference)
|
The results of a systematic quantitative validation of PEDFLOW based on the experimental data from FZJ are presented. Uni- directional flow experiments, totaling 28 different combinations with varying entry, corridor and exit widths, were considered. The condition imposed on PEDFLOW was that all the cases should be run with the same input parameters. The exit times and fundamental diagrams for the measuring region were evaluated and compared. This validation process led to modifications and enhancements of the model underlying PEDFLOW. The preliminary conclusions indicate that the results agree well for densities smaller than and a good agreement is observed even at high densities for the corridors with bcor = 2.4 m, and bcor = 3.0 m. For densities between 1 and the specific flow and velocities are underpredicted by PEDFLOW.
Published on 01/01/2014
DOI: 10.1016/j.trpro.2014.09.081
Licence: CC BY-NC-SA license