m (Cinmemj moved page Draft Samper 133507090 to Chacon et al 2009a)
(No difference)

Revision as of 10:48, 26 April 2019

Published in Structural Health Monitoring Vol. 8 (3), pp. 195-205, 2009
DOI: 10.1177/1475921708100779

Abstract

In this paper, an experimental test performed on a hybrid steel plate girder was subjected to concentrated loads at the end of an unstiffened panel is presented. This load was intended to produce a typical reaction of the piers while launching steel girders in bridges. In this test, strain measurements were taken with conventional pre-wired gauges as well as with newly developed wirelessly connected strain-measuring system. Both measurements were carefully compared and the accuracy of the developed system was demonstrated. Results were also compared with numerical simulations deployed with FE models and on such a basis; the reliability of the developed wireless system was proven. Finally, suggestions of potential research trends in this area are provided.

The PDF file did not load properly or your web browser does not support viewing PDF files. Download directly to your device: Download PDF document
Back to Top

Document information

Published on 01/01/2009

DOI: 10.1177/1475921708100779
Licence: CC BY-NC-SA license

Document Score

0

Times cited: 13
Views 6
Recommendations 0

Share this document

claim authorship

Are you one of the authors of this document?