Porto Romano port complex new facilities are part of the expansion plans of Durres port and its modernisation. However, the relocation site presented many significant spatial and geotechnical challenges to be considered and mitigated.  Soil conditions and the country’s high seismic activity meant the project required extensive feasibility and technical studies to find a safe and sustainable approach. For a detailed geological and geotechnical investigation of the area, various geotechnical, geophysical tests were carried out such as: borings, SPT test, CPTU test, Seismic refraction, MASW, Downhole and HVSR allowing to obtain the fundamental resonance frequency of the ground. Field recordings per each layer were than compared and calibrated to the results and tests performed in the laboratory. The construction site displayed a variety of soils from soft to firm silty Clays, to loose to medium dense silty Sands and layers with high organic content. During execution of SPT tests, sandy layers gave more satisfactory results, meanwhile, for silty CLAY layers, the results of CPTU testing were considered in analysis. This detailed soil investigation and characterization served to properly design the new port facilities, identify, and protect from the liquefaction phenomena at this specific site.
 
Porto Romano port complex new facilities are part of the expansion plans of Durres port and its modernisation. However, the relocation site presented many significant spatial and geotechnical challenges to be considered and mitigated.  Soil conditions and the country’s high seismic activity meant the project required extensive feasibility and technical studies to find a safe and sustainable approach. For a detailed geological and geotechnical investigation of the area, various geotechnical, geophysical tests were carried out such as: borings, SPT test, CPTU test, Seismic refraction, MASW, Downhole and HVSR allowing to obtain the fundamental resonance frequency of the ground. Field recordings per each layer were than compared and calibrated to the results and tests performed in the laboratory. The construction site displayed a variety of soils from soft to firm silty Clays, to loose to medium dense silty Sands and layers with high organic content. During execution of SPT tests, sandy layers gave more satisfactory results, meanwhile, for silty CLAY layers, the results of CPTU testing were considered in analysis. This detailed soil investigation and characterization served to properly design the new port facilities, identify, and protect from the liquefaction phenomena at this specific site.
 +
 +
== Full Paper ==
 +
<pdf>Media:Draft_Sanchez Pinedo_722639475251.pdf</pdf>

Latest revision as of 14:50, 6 June 2024

Abstract

Porto Romano port complex new facilities are part of the expansion plans of Durres port and its modernisation. However, the relocation site presented many significant spatial and geotechnical challenges to be considered and mitigated. Soil conditions and the country’s high seismic activity meant the project required extensive feasibility and technical studies to find a safe and sustainable approach. For a detailed geological and geotechnical investigation of the area, various geotechnical, geophysical tests were carried out such as: borings, SPT test, CPTU test, Seismic refraction, MASW, Downhole and HVSR allowing to obtain the fundamental resonance frequency of the ground. Field recordings per each layer were than compared and calibrated to the results and tests performed in the laboratory. The construction site displayed a variety of soils from soft to firm silty Clays, to loose to medium dense silty Sands and layers with high organic content. During execution of SPT tests, sandy layers gave more satisfactory results, meanwhile, for silty CLAY layers, the results of CPTU testing were considered in analysis. This detailed soil investigation and characterization served to properly design the new port facilities, identify, and protect from the liquefaction phenomena at this specific site.

Full Paper

The PDF file did not load properly or your web browser does not support viewing PDF files. Download directly to your device: Download PDF document
Back to Top

Document information

Published on 06/06/24
Submitted on 06/06/24

Volume Data-driven site characterization, 2024
DOI: 10.23967/isc.2024.251