(Created blank page) |
|||
Line 1: | Line 1: | ||
+ | |||
+ | ==Abstract== | ||
+ | . One of the prevalent challenges in the design, numerical analysis and verification of structural membranes lies in the non-linearity of their load-response curves. Structural analysis has to be performed with a geometrically non-linear approach, due to the interaction of form and forces and thus a linear extrapolation or combination of analyis results is not possible. The appropriate modeling of the environmental impacts (such as wind and snow) also has a significant influence on the analysis results. Furthermore, non-linear material behavior can be of interest. The resulting load-response curves (e.g. stresses, deformations) are typically non-linear and their interpretation towards the underlying safety requirements is not straight forward. In addition, the prestress also has a major influence on membranes' structural behavior. However, the current European regulations for the proof of the limit states (ULS and SLS) of any building requires a simplified categorization of the structural behavior. This research investigates the load-bearing behavior of typical re-occurring membrane shapes in the context of current verification requirements. Typical load cases are applied and the structural behavior is shown under consideration of the mentioned non-linearities. |
. One of the prevalent challenges in the design, numerical analysis and verification of structural membranes lies in the non-linearity of their load-response curves. Structural analysis has to be performed with a geometrically non-linear approach, due to the interaction of form and forces and thus a linear extrapolation or combination of analyis results is not possible. The appropriate modeling of the environmental impacts (such as wind and snow) also has a significant influence on the analysis results. Furthermore, non-linear material behavior can be of interest. The resulting load-response curves (e.g. stresses, deformations) are typically non-linear and their interpretation towards the underlying safety requirements is not straight forward. In addition, the prestress also has a major influence on membranes' structural behavior. However, the current European regulations for the proof of the limit states (ULS and SLS) of any building requires a simplified categorization of the structural behavior. This research investigates the load-bearing behavior of typical re-occurring membrane shapes in the context of current verification requirements. Typical load cases are applied and the structural behavior is shown under consideration of the mentioned non-linearities.
Published on 18/10/23
Submitted on 18/10/23
Volume Numerical Methods and Modeling for Lightweight Structures, 2023
DOI: 10.23967/c.membranes.2023.041
Licence: CC BY-NC-SA license
Are you one of the authors of this document?