(Created page with " <div class="center" style="width: auto; margin-left: auto; margin-right: auto;"> J. Castro<sup>a</sup>, F. Sket<sup>a</sup>, C. González<sup>a,b</sup></div> <div class="ce...")
 
 
(13 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 
 
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
 
J. Castro<sup>a</sup>, F. Sket<sup>a</sup>, C. González<sup>a,b</sup></div>
 
 
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
 
<span style="text-align: center; font-size: 75%;"><sup>a</sup>Instituto IMDEA Materiales, C/Eric Kandel, 2, 28906 Getafe, Madrid, España</span></div>
 
 
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
 
<span style="text-align: center; font-size: 75%;"><sup>b</sup> Departamento de Ciencia de los Materiales, Universidad Politécnica de Madrid, C/ Prof. Aranguren, 3, 28040 Madrid, España</span></div>
 
 
{| style="width: 87%;border-collapse: collapse;"
 
|-
 
|  colspan='2'  style="vertical-align: top;"|<big>Un estudio de los fenómenos de capilaridad a escala microscópica en materiales compuestos mediante técnicas de tomografía de rayos X</big>
 
 
 
|-
 
|  style="border-bottom: 1pt solid black;vertical-align: top;"|<span style="text-align: center; font-size: 75%;"> [[Image:Draft_Porcar_507359298-image1.png|54px]] </span>
 
|  style="vertical-align: top;"|
 
|-
 
|  style="border-top: 1pt solid black;border-bottom: 1pt solid black;vertical-align: top;"|<span style="text-align: center; font-size: 75%;">Historia del artículo:</span>
 
 
<span style="text-align: center; font-size: 75%;">Recibido 5 de Mayo 2017</span>
 
 
<span style="text-align: center; font-size: 75%;">En la versión revisada 5 de Mayo 2017</span>
 
 
<span style="text-align: center; font-size: 75%;">Aceptado 31 de Mayo 2017</span>
 
 
<span style="text-align: center; font-size: 75%;">Accesible online 21 de Junio 2017</span>
 
|  rowspan='4' style="vertical-align: top;"|<span style="text-align: center; font-size: 75%;">Uno de los principales problemas asociados a la fabricación de materiales compuestos mediante ruta líquida, inyección, infusión, etc. es la generación de porosidad. La optimización de las propiedades de los compuestos resultantes pasa por un mejor entendimiento de los mecanismos de formación y transporte de poros. En los canales entre mazos de fibras, la resina fluye controlada por el gradiente de presiones y su viscosidad. Sin embargo, dentro de los mazos de fibra, la resina fluye como consecuencia de la presión de capilaridad. Como consecuencia, si las fuerzas viscosas y de capilaridad no están compensadas, se produce flujo no homogéneo y la formación de poros bien sea entre los mazos de fibras o internamente a los mazos. En este trabajo se presenta un estudio sistemático del proceso de mojado espontáneo de un mazo de fibra de vidrio E, ensayo de </span><span style="text-align: center; font-size: 75%;">''wicking'', utilizando varios fluidos con distintas propiedades, viscosidad, tensión superficial y ángulo de contacto. También se han realizado ensayos de infusión por vacío en mazos de fibras. La visualización de la posición del frente del flujo de resina a escala microscópica, así como la formación de los meniscos entre fibras se ha realizado mediante técnicas de tomografía de rayos X utilizando radiación de sincrotrón. Los volúmenes reconstruidos han permitido obtener información cuantitativa detallada sobre la geometría de los meniscos que se producen como consecuencia de la tensión superficial que opera a dicha escala. Estas técnicas de caracterización constituyen una herramienta fundamental para la optimización del procesado de materiales compuestos. </span>
 
 
 
|-
 
|  style="border-top: 1pt solid black;vertical-align: top;"|<span style="text-align: center; font-size: 75%;">Palabras clave:</span>
 
 
<span style="text-align: center; font-size: 75%;">Inyección</span>
 
 
<span style="text-align: center; font-size: 75%;">Infusión</span>
 
 
<span style="text-align: center; font-size: 75%;">Porosidad</span>
 
 
<span style="text-align: center; font-size: 75%;">Capillaridad</span>
 
 
<span style="text-align: center; font-size: 75%;">Tomografía rayos X</span>
 
|-
 
|  style="border-top: 1pt solid black;vertical-align: top;"|
 
|-
 
|  colspan='2'  style="vertical-align: top;"|<big>A microlevel capillary study in composite materials by X-ray tomography </big>
 
|-
 
|  style="border-bottom: 1pt solid black;vertical-align: top;"|<span style="text-align: center; font-size: 75%;"> [[Image:Draft_Porcar_507359298-image2.png|54px]] </span>
 
|  style="vertical-align: top;"|
 
|-
 
|  style="border-top: 1pt solid black;border-bottom: 1pt solid black;vertical-align: top;"|<span style="text-align: center; font-size: 75%;">Keywords:</span>
 
 
<span style="text-align: center; font-size: 75%;">Injection</span>
 
 
<span style="text-align: center; font-size: 75%;">Infusion</span>
 
 
<span style="text-align: center; font-size: 75%;">Porosity</span>
 
 
<span style="text-align: center; font-size: 75%;">Capillary</span>
 
 
<span style="text-align: center; font-size: 75%;">X-ray tomography</span>
 
|  rowspan='2' style="vertical-align: top;"|<span id='_GoBack'>One of the main problems associated with the manufacture of composite materials by liquid moulding (injection, infusion, etc.) is the generation of porosity. The optimization of the properties of the composites passes through a better understanding of the mechanisms of pore formation and transport. This pore formation is associated with a non-homogeneity of resin flow during the manufacturing process as a consequence of the double-scale porosity present in textile preforms. In the channels between bundles of fibers, the resin flows controlled by the pressure gradient and its viscosity. However, within the fiber bundles, the resin flows as a result of the capillary pressure. As a consequence, if the viscous and capillary forces are not balanced, non-homogeneous local flow occurs and the formation of pores, either between the fiber bundles, or internally to the bundles is produced.In this work a systematic study of the spontaneous wetting process of an E glass fiber bundle through wicking tests, using several fluids with different properties, viscosity, surface tension and contact angle is presented. The visualization of the front position of the resin flow at microscopic scale, as well as the formation of the menisci between fibers has been performed using X-ray tomography techniques using synchrotron radiation. The reconstructed volumes have made it possible to obtain detailed quantitative information on the geometry of the menisci which occur as a consequence of the surface tension operating at such scale. These characterization techniques constitute a fundamental tool for the optimization of the processing of composite materials buy liquid moulding.</span>
 
|-
 
|  style="border-top: 1pt solid black;vertical-align: top;"|
 
|}
 
 
 
 
==1 Introduction==
 
==1 Introduction==
  
Line 88: Line 19:
  
  
[[Image:Draft_Porcar_507359298-picture-Agrupar 6.svg|center|600px]]
+
[[File:Captura de pantalla 2022-11-01 192352.png|centre|600x600px]]
 
+
 
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
 
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
<span style="text-align: center; font-size: 75%;">'''Figure 1.''' Different flow regimes depending of the modified capillary number: a) Ca*<10<sup>-3</sup> b) 10<sup>-3</sup><Ca*<10<sup>-</sup><sup>2</sup> c) Ca*>10<sup>-</sup><sup>2</sup></span></div>
+
<span style="text-align: center; font-size: 75%;">'''Figure 1.''' Different flow regimes depending of the modified capillary number: a) Ca*<10<sup>-3</sup> b) 10<sup>-3</sup><Ca*<10<sup>-</sup><sup>2</sup> c) Ca*>10<sup>-</sup><sup>2</sup>.</span></div>
  
 
The effect of surface tension in the capillary forces are often neglected in many process, for example in LCM at the microscopic scale. However, the prominence of capillary forces in the flow process at the microscale is the cause for creating some of the voids in the material. Therefore, several authors started to work in this topic in the field of composites [7,8,9] and is one of the main goals for this work. Here, we will focus on understanding the fundaments of the physics of infiltration at the microlevel using advanced characterization techniques based on X-ray tomography through the spontaneous and forced impregnation of individual dry fiber bundles.
 
The effect of surface tension in the capillary forces are often neglected in many process, for example in LCM at the microscopic scale. However, the prominence of capillary forces in the flow process at the microscale is the cause for creating some of the voids in the material. Therefore, several authors started to work in this topic in the field of composites [7,8,9] and is one of the main goals for this work. Here, we will focus on understanding the fundaments of the physics of infiltration at the microlevel using advanced characterization techniques based on X-ray tomography through the spontaneous and forced impregnation of individual dry fiber bundles.
Line 112: Line 42:
 
<span style="text-align: center; font-size: 75%;">'''Table 1'''. Properties of the fluids used in the study</span></div>
 
<span style="text-align: center; font-size: 75%;">'''Table 1'''. Properties of the fluids used in the study</span></div>
  
 +
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
 
{| style="width: 100%;border-collapse: collapse;"  
 
{| style="width: 100%;border-collapse: collapse;"  
 
|-
 
|-
Line 138: Line 69:
 
|  style="border-bottom: 2pt solid black;text-align: center;vertical-align: top;"|<span style="text-align: center; font-size: 75%;">56±0.2</span>
 
|  style="border-bottom: 2pt solid black;text-align: center;vertical-align: top;"|<span style="text-align: center; font-size: 75%;">56±0.2</span>
 
|}
 
|}
 
+
</div>
  
 
The surface tension was measured using a modified Wilhelmy test. To this end, a dry filter paper 1x2mm<sup>2</sup> and 0.3mm thickness is used to ensure that the contact angle with the fluid is very small &#x03b8;=0 allowing a direct measurement by means of the force transmitted during the extraction of the wet paper as it is shown in Figure 2a) and b). A fiber tester apparatus FAVIMAT with 0.1 µN resolution was adapted for this purpose with a small fluid container for the measurements of the surface energy, Figure 2c).
 
The surface tension was measured using a modified Wilhelmy test. To this end, a dry filter paper 1x2mm<sup>2</sup> and 0.3mm thickness is used to ensure that the contact angle with the fluid is very small &#x03b8;=0 allowing a direct measurement by means of the force transmitted during the extraction of the wet paper as it is shown in Figure 2a) and b). A fiber tester apparatus FAVIMAT with 0.1 µN resolution was adapted for this purpose with a small fluid container for the measurements of the surface energy, Figure 2c).
Line 149: Line 80:
 
[[Image:Draft_Porcar_507359298-image7.png|center|324px]]
 
[[Image:Draft_Porcar_507359298-image7.png|center|324px]]
  
 
+
|'''c)'''
 
|  style="vertical-align: top;width: 40%;"|
 
|  style="vertical-align: top;width: 40%;"|
 
[[Image:Draft_Porcar_507359298-image8.jpeg|center|168px]]
 
[[Image:Draft_Porcar_507359298-image8.jpeg|center|168px]]
c)
+
 
 
|-
 
|-
 
|  colspan='2'  style="text-align: center;vertical-align: top;"|<span style="text-align: center; font-size: 75%;">'''Figure 2.''' Modified Wilhelmy test, a) With fluid contact, b) Without fluid contct, c) FAVIMAT fiber tester.</span>  
 
|  colspan='2'  style="text-align: center;vertical-align: top;"|<span style="text-align: center; font-size: 75%;">'''Figure 2.''' Modified Wilhelmy test, a) With fluid contact, b) Without fluid contct, c) FAVIMAT fiber tester.</span>  
 
|}
 
|}
 
  
 
Although the measurement of the viscosity and surface tension is straightforward, the corresponding measurement of the contact angle &#x03b8; deserves some additional considerations. First, the influence of the current sizing and secondly, the processing conditions, as for instance, humidity, vacuum, etc. Thus, a detailed technique measuring the local variations at the fiber scale is required and high resolution X-ray tomography could be potentially the most appropriate technique for such purposes.
 
Although the measurement of the viscosity and surface tension is straightforward, the corresponding measurement of the contact angle &#x03b8; deserves some additional considerations. First, the influence of the current sizing and secondly, the processing conditions, as for instance, humidity, vacuum, etc. Thus, a detailed technique measuring the local variations at the fiber scale is required and high resolution X-ray tomography could be potentially the most appropriate technique for such purposes.
Line 177: Line 107:
 
|  colspan='2'  style="vertical-align: top;"|<span style="text-align: center; font-size: 75%;">'''Figure 3.''' a) System used to reproduce wicking tests under X-ray radiation for tomography, b) Detail of the local meniscus in the wicking area in contact with the atmosphere formed with resin H (flow direction is vertical). </span>
 
|  colspan='2'  style="vertical-align: top;"|<span style="text-align: center; font-size: 75%;">'''Figure 3.''' a) System used to reproduce wicking tests under X-ray radiation for tomography, b) Detail of the local meniscus in the wicking area in contact with the atmosphere formed with resin H (flow direction is vertical). </span>
 
|}
 
|}
 
  
 
On the other hand, the container at the bottom works as a reservoir, holds the sample and also attaches the system to the rotational stage of an XCT system. The container has the shape of a cylinder and has a cover on the top face. The cover has a short and thin cylinder on the top surface which allows to stick the sample to the container. The cover has four holes since the pressure inside the container must be atmospheric.
 
On the other hand, the container at the bottom works as a reservoir, holds the sample and also attaches the system to the rotational stage of an XCT system. The container has the shape of a cylinder and has a cover on the top face. The cover has a short and thin cylinder on the top surface which allows to stick the sample to the container. The cover has four holes since the pressure inside the container must be atmospheric.
Line 186: Line 115:
 
<span style="text-align: center; font-size: 75%;">'''Table 2'''. Contact angle with three of the fluids</span></div>
 
<span style="text-align: center; font-size: 75%;">'''Table 2'''. Contact angle with three of the fluids</span></div>
  
 +
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
 
{| style="width: 63%;border-collapse: collapse;"  
 
{| style="width: 63%;border-collapse: collapse;"  
 
|-
 
|-
Line 200: Line 130:
 
|  style="border-bottom: 2pt solid black;text-align: center;vertical-align: top;"|<span style="text-align: center; font-size: 75%;">35±5</span>
 
|  style="border-bottom: 2pt solid black;text-align: center;vertical-align: top;"|<span style="text-align: center; font-size: 75%;">35±5</span>
 
|}
 
|}
 
+
</div>
  
 
==3  In-situ micro flow assesment==
 
==3  In-situ micro flow assesment==
Line 210: Line 140:
  
 
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
 
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
<span style="text-align: center; font-size: 75%;">'''Figure 4.''' a) </span>Sketch of the infiltration device. b) Picture of the experiment performed in PETRA III Synchrotron.</div>
+
<span style="text-align: center; font-size: 75%;">'''Figure 4.''' a) Sketch of the infiltration device. b) Picture of the experiment performed in PETRA III Synchrotron.</span></div>
  
 
The vacuum is applied through a vacuum pump. The pump used can reach up to -0.95bar. It is connected to the outlet of the device through a catch pot to avoid fluid infiltration into the vacuum pump. The outlet port is situated in a mechanised piece made of Aluminium. A cut head of a 5ml syringe is located on the top part of this piece. Hence, a 0.8 mm in diameter needle can be positioned on the syringe and vacuum can be conducted through both. Another needle is also introduced into the bottom side of the sample. The tested samples during in-situ infiltration correspond to (1, 2 or 3) tows of E-glass inside a polyethylene (PE) vacuum bag. PE was selected due to the higher X-ray resistance with respect to usual Nylon. The vacuum bag has a thickness of 0.4mm while the tow measures 54 mm in length and 4 mm in width. To avoid leaks near the needles connection, a tacky tape is utilised to seal the sample. The remaining perimeter of the bag is thermally sealed in order to avoid tacky tape (a material with high X-ray absorption coefficient) and therefore extra absorbing material in the Field of View (FOV).
 
The vacuum is applied through a vacuum pump. The pump used can reach up to -0.95bar. It is connected to the outlet of the device through a catch pot to avoid fluid infiltration into the vacuum pump. The outlet port is situated in a mechanised piece made of Aluminium. A cut head of a 5ml syringe is located on the top part of this piece. Hence, a 0.8 mm in diameter needle can be positioned on the syringe and vacuum can be conducted through both. Another needle is also introduced into the bottom side of the sample. The tested samples during in-situ infiltration correspond to (1, 2 or 3) tows of E-glass inside a polyethylene (PE) vacuum bag. PE was selected due to the higher X-ray resistance with respect to usual Nylon. The vacuum bag has a thickness of 0.4mm while the tow measures 54 mm in length and 4 mm in width. To avoid leaks near the needles connection, a tacky tape is utilised to seal the sample. The remaining perimeter of the bag is thermally sealed in order to avoid tacky tape (a material with high X-ray absorption coefficient) and therefore extra absorbing material in the Field of View (FOV).

Latest revision as of 20:36, 1 November 2022

1 Introduction

It is essential to understand the cause of void formation in order to lower voids content in Liquid Moulding Manufacturing (LCM). Voids can be originated from the volatilization of dissolved gases in the fluid or also from initial air bubbles content in the resin [1]. Nevertheless, the major responsible effect for void generation is the mechanical entrapment of air caused by the different paths where resin flows through the preform. The non-homogeneous spatial distribution of the fabric produces the existence of two different flows mechanisms at the mesoscopic level. Firstly, in regions with high permeability, the space between fibre bundles, the viscous forces dominate, while, secondly, inside the fibre bundles capillary forces prevail. This competition between viscous and capillary forces is the main explanation of air entrapment in LCM. Experimental results have led to conclude that this competition between viscous and capillary forces can be described by the non-dimensional modified capillary number defined as Ca*[2,3,4]

(1)


where μ stands for viscosity, v is the resin average velocity, γ is the surface tension and θ refers to the contact angle between resin and fibre. Patel et al. [5] and Rohatgi et al. [6] showed experimental evidence of the existence of a single master curve of void content plotted as a function of the modified capillary number. These authors also reported that below a certain value of the capillary number, Ca*<10-3, capillary forces domain the flow over the viscous forces, Figure 1a). As explained above, macropores are then generated in the space between fibre bundles under these conditions. On the other hand, microvoids are generated inside the fibre tows when viscous forces domain the flow, Ca*>10-2, as it can be seen in

Figure 1c). Optimizing this two flows (intratow and intertow) will result in components with reduced void content which is produced in the range of 10-3<Ca*<10-2 as it is shown in Figure 1b).


Captura de pantalla 2022-11-01 192352.png
Figure 1. Different flow regimes depending of the modified capillary number: a) Ca*<10-3 b) 10-3<Ca*<10-2 c) Ca*>10-2.

The effect of surface tension in the capillary forces are often neglected in many process, for example in LCM at the microscopic scale. However, the prominence of capillary forces in the flow process at the microscale is the cause for creating some of the voids in the material. Therefore, several authors started to work in this topic in the field of composites [7,8,9] and is one of the main goals for this work. Here, we will focus on understanding the fundaments of the physics of infiltration at the microlevel using advanced characterization techniques based on X-ray tomography through the spontaneous and forced impregnation of individual dry fiber bundles.

2 Methodology

2.1 Materials and experimental techniques

Two epoxy resins and corn syrup resin blends (70% corn and 30% water) were used in the experiments. D.E.R. ™ 736 (a Polymer of epichlorohydrin-polyglycol) is an epoxy resin with a very low viscosity. It can be easily blended with D.E.R. ™ 332 (a high viscosity and high purity bisphenol A diglycidylether) in order to obtain a target viscosity. Up onwards, ResinL refers to a blend of D.E.R. ™ 736 (50%) and D.E.R. ™ 332 (50%) by weight, in other words, a low viscosity resin while ResinH to pure D.E.R. ™ 332, a high viscosity resin. Besides, as explained above, it may be required to incorporate to the fluid some agents to enhance X-ray contrast.

Epoxy resins are not aqueous solutions and therefore salts are not soluble into them. So, in this case, an organic compound with a high composition of bromine was used. Due to the great ease to dissolve it into epoxy resins, 4-Bromophenol (BrC6H4OH) was added. This substance creates a higher contrast between fibres and fluid. A 10% by weight of the dopant is added to the blend. In these case, ResinLB and ResinHB refer to the doped with 4-Bromophenol versions of the previous ResinL and ResinH described.

E-glass tows containing around 2000 filaments were extracted from a plain-woven fabric. Each single glass fibre has a diameter in the range of 16±2 μm. Depending on the supplier, fibres are coated with a material called sizing used to improve wetting of fibres during impregnation. The interaction with the fluid by means of the contact angle is, therefore, dependent on the properties of the sizing used during fiber and fabric manufacturing and the environmental conditions.

2.2 Properties of the fluids

A rotational viscometer Fungilab Alpha L with resolution of 0.1 mPas was used in the experiments to measure the fluid viscosity μ. The results are presented in Table 1. The viscosity is slightly modified by the presence of the dopants for visualization enhancement.

Table 1. Properties of the fluids used in the study
Liquid μ (mPas) μ  (mN m-1)
Corn syrup (70-30) 157 60±0.5
ResinL 204 48±0.2
ResinLB 289 48±0.2
ResinH 2805 61±0.5
ResinHB 1639 56±0.2

The surface tension was measured using a modified Wilhelmy test. To this end, a dry filter paper 1x2mm2 and 0.3mm thickness is used to ensure that the contact angle with the fluid is very small θ=0 allowing a direct measurement by means of the force transmitted during the extraction of the wet paper as it is shown in Figure 2a) and b). A fiber tester apparatus FAVIMAT with 0.1 µN resolution was adapted for this purpose with a small fluid container for the measurements of the surface energy, Figure 2c).

The results obtained are presented for the different fluids analyzed and do not differ between doped fluids. Previously, the technique was validated with well-established values reported in the literature for distilled water, ethanol and olive oil.

Draft Porcar 507359298-image7.png
c)
Draft Porcar 507359298-image8.jpeg
Figure 2. Modified Wilhelmy test, a) With fluid contact, b) Without fluid contct, c) FAVIMAT fiber tester.

Although the measurement of the viscosity and surface tension is straightforward, the corresponding measurement of the contact angle θ deserves some additional considerations. First, the influence of the current sizing and secondly, the processing conditions, as for instance, humidity, vacuum, etc. Thus, a detailed technique measuring the local variations at the fiber scale is required and high resolution X-ray tomography could be potentially the most appropriate technique for such purposes.

A wicking experiment is performed in a bundle of fibers driven only by capillary forces without the application of vacuum. A specific apparatus was designed to study the wicking experiment capillary rise in a fiber bundle tube over time with detailed measurements of the contact angle at the air/fluid/fiber interfaces as it is sketched in Figure 3a).

The sample consists of a tube made of glass. A bundle of E-glass fibres is introduced into the tube. The fibre volume fraction was close to the target volume fraction in practical manufacturing by vacuum infusion (≈50%).

Draft Porcar 507359298-image9-c.png

a)


Draft Porcar 507359298-image10-c.jpeg

b)

Figure 3. a) System used to reproduce wicking tests under X-ray radiation for tomography, b) Detail of the local meniscus in the wicking area in contact with the atmosphere formed with resin H (flow direction is vertical).

On the other hand, the container at the bottom works as a reservoir, holds the sample and also attaches the system to the rotational stage of an XCT system. The container has the shape of a cylinder and has a cover on the top face. The cover has a short and thin cylinder on the top surface which allows to stick the sample to the container. The cover has four holes since the pressure inside the container must be atmospheric.

The X-ray tomography system allowed the direct access to the meniscus formed locally between the fibers in the contact with the atmosphere, Figure 3b). The results of the measurements over more than twenty contact angle are summarized in Table 2 for three of the fluids analyzed (corn syrup and resins LB and HB). These results were obtained using Synchrotron radiation from both ESRF (Grenoble, Francia) and Petra III Syncrotron (Hamburgo, Aluminio).

Table 2. Contact angle with three of the fluids
Liquid θ (º)
Corn syrup (70-30) 75±7.5
ResinLB 45±5
ResinHB 35±5

3 In-situ micro flow assesment

This set of experiments is devoted to visualize the flow front of resin during the infusion of a single tow using the methodology developed by Vilà et al. [10].


Draft Porcar 507359298-image11-c.png
Figure 4. a) Sketch of the infiltration device. b) Picture of the experiment performed in PETRA III Synchrotron.

The vacuum is applied through a vacuum pump. The pump used can reach up to -0.95bar. It is connected to the outlet of the device through a catch pot to avoid fluid infiltration into the vacuum pump. The outlet port is situated in a mechanised piece made of Aluminium. A cut head of a 5ml syringe is located on the top part of this piece. Hence, a 0.8 mm in diameter needle can be positioned on the syringe and vacuum can be conducted through both. Another needle is also introduced into the bottom side of the sample. The tested samples during in-situ infiltration correspond to (1, 2 or 3) tows of E-glass inside a polyethylene (PE) vacuum bag. PE was selected due to the higher X-ray resistance with respect to usual Nylon. The vacuum bag has a thickness of 0.4mm while the tow measures 54 mm in length and 4 mm in width. To avoid leaks near the needles connection, a tacky tape is utilised to seal the sample. The remaining perimeter of the bag is thermally sealed in order to avoid tacky tape (a material with high X-ray absorption coefficient) and therefore extra absorbing material in the Field of View (FOV).

The top part of the device was designed to control the height of the reservoir of fluid and the position of the piston. A syringe of 2ml and its piston operate as container and piston. A thread allows to control the height of the holder and fixes it to the device to avoid movements produced during the XCT measurements. Besides, another thread controls the height of the piston. The user can rotate the thread letting the piston to advance and at some point, a drop falls into the needle. Right after, as soon as the liquid deposited in the needle weights enough, the vacuum absorbs it and the fluid infiltrates into the vacuum bag. This method allows an infiltration step-by-step controlled by the user, Figure 4a).

In the following two S-XCT observations of different wetting regimes are presented, Figure 4b). The first case uses corn syrup as fluid and the results are obtained from literature [10]. A representative tomogram of the central region with different local fibre distribution of the tow depicted in Figure 5. It should be remarked that SXCT measurements were carried out under quasi-static conditions and no fluid displacements were detected during data acquisition because they would have led to image blurring effects.

Draft Porcar 507359298-image12-c.png a) Draft Porcar 507359298-image13.jpeg b)
Figure 5. Cross section of the fiber bundle during infusion of a) corn-syrup, b) Resin LB, showing the dry and wet areas. Corn-syrup is infiltrated maninly in the open channels while Resin LB pass through highly packed fibers.

The results obtained in the tomograms clearly showed two different behaviours. First, the infiltration with corn-syrup is produced mainly in open channels with low volume fraction of fibers where the capillary forces are considered negligible. The large contact angle of the corn syrup blend with the glass fibers (θ=75±7.5º) favours the flow through open channels rather than through the highly packed fibers where the capillary forces are considered mainly as drag forces. On the other hand, the flow with Resin LB was much easier in the packed fiber region due to the large capillary forces driven by the lower contact angle (θ=45±5º).

4 References

[1] W.R. Stabler, G.B. Tatterson, R.L. Sadler and A.H. El-Shiekh, 1992 “Void minimization in the Manufacture of Carbon Fiber Composites by Resin Transfer Moulding” SAMPE Q. 23 January, pp 38-42.

[2] Y.K. Hamidi, L. Aktas, M. Altan, Formation of microscopic voids in resin transfer molded compoistes, J.Eng. Mater. Technol. 126 (2004) 420-426.

[3] C.H. Park, A. Lebel, A. Saouab, J. Brard, W.I. Lee, Modelling and simulation of voids and saturarion in liquid composite molding processes. Compos. Part A Appl. Sci. Manuf 42 (2011)

[4] N. Patel, L.J. Lee, Effects of fiber mat architecture on void formation and removal in liquid composite molding, Polym. Compos. 16 (1995) 386-399.

[5] Patel, N., Rohatgi, V., and Lee. J. L., 1995 "Micro Scale Flow Behaviour and Void Formation Mechanism During Impregnation of Uniderctional Stitched Fiberglass Mat", Polym. Eng. Sci., 35. pp. 837-851.

[6] Rohatgi, V., Patel, N. and Lee, J.L., 1996, "Experimental Investigation of Flow Induced Micro-Voids During Impregnation of Unidirectional Stitched Fiberglass Mat." Poly. Compos., 17. pp. 161-170.

[7] J. Verrey, V. Michaud and J-A.E. Manson, “Dynamic capillary effects in liquid composite moulding with non-crimp fabrics” , Composites: Part A 37 (2006) 92-102

[8] S. Azizian and M. Hemmati, “Surface Tension of Binary Mixtures of Ethanol+Ethylene Glycolfrom 20 to 50°C”, J. Chem. Eng. Data 2003, 48,662-663.

[9] M. Li, S. Wang, Y. Gu, Z. Zhang, Y. Li and K. Potter, “Dynamic capillary impact on longitudinal micro-flow in vacuum assisted impregnation and the unsaturated permeability of inner fiber tows” Composites Science and Technology 70 (2010) 1628-1636

[10] J. Vilà, F. Sket, F. Wilde, G. Requena, C. González and J. Llorca, “An in-situ investigation of microscopic infusion and void transport during vacuum-assisted infiltration by means of X-ray computed tomography”, Composites Science and Technology, 119 (2015) 12-19

Back to Top

Document information

Published on 31/03/22
Accepted on 31/03/22
Submitted on 30/03/22

Volume 03 - Comunicaciones Matcomp17 (2019), Issue Núm. 3 - Procesos de Fabricación II y Materiales Avanzados, 2022
DOI: 10.23967/r.matcomp.2022.03.012
Licence: Other

Document Score

0

Views 3
Recommendations 0

Share this document

claim authorship

Are you one of the authors of this document?