(Created page with " == Abstract == International audience; The work presented here is part of a larger study concerning the analysis of electrical stress and degradation phenomena of electrical...")
 
m (Scipediacontent moved page Draft Content 166653122 to Benmamas et al 2017a)
 
(No difference)

Latest revision as of 17:18, 3 February 2021

Abstract

International audience; The work presented here is part of a larger study concerning the analysis of electrical stress and degradation phenomena of electrical insulation of low voltage machines fed by Pulse Width Modulation (PWM) controlled inverter. The goal is to assess the risk of partial discharge (PD) in stator windings of rotating machines. In this objective, two complementary approaches are adopted: electrostatic simulations using Finite Element Method (FEM) in 2D approximation, and experimental measurements. The model seems to be a good tool allowing an approximation of PD occurrence in a given wire type. In the experimental part of this study, a simple and efficient method to detecting PD under PWM controlled voltage is presented.


Original document

The different versions of the original document can be found in:

https://academic.microsoft.com/#/detail/2743821940
http://dx.doi.org/10.1109/eic.2017.8004701
Back to Top

Document information

Published on 01/01/2017

Volume 2017, 2017
DOI: 10.1109/eic.2017.8004701
Licence: CC BY-NC-SA license

Document Score

0

Views 1
Recommendations 0

Share this document

claim authorship

Are you one of the authors of this document?