m (Scipediacontent moved page Draft Content 751489993 to Pitts 1979a) |
|||
(One intermediate revision by the same user not shown) | |||
Line 2: | Line 2: | ||
== Abstract == | == Abstract == | ||
− | + | preliminary study of the feasibility of using existing drinking water supply systems to provide hot water for heating purposes to a typical 140-home subdivision has been undertaken. This preliminary study has centered on (i) types of municipal water system designs and effects of system design upon heating use; (ii) methods of using low-to-moderate temperature water for heating purposes and possible institutional barriers; (iii) identification and description of a typical residential community suitable for hot water heating; (iv) evaluation of thermal losses in the uninsulated main distribution system from the main pumping station having assumed geothermal heating to the subdivision; (v) evaluation of thermal losses in the uninsulated street mains in the subdivision; (vi) estimation of size and cost of the pumping station main heat exchanger to supply geothermal energy to the drinking water; (vii) sizing of individual house heat exchangers; (viii) pumping and power requirements to supply the increased water flow rate through the subdivision street water distribution lines; and (ix) pumping and piping requirements to provide heating water flow from the street lines to a typical residence. From the results obtained thus far, it would appear that the use of existing uninsulated water supply systems will be advantageous more » in many communities having nearby low-to-moderate temperature geothermal resources. « le | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
Line 18: | Line 13: | ||
* [https://digital.library.unt.edu/ark:/67531/metadc1101687/m2/1/high_res_d/5905644.pdf https://digital.library.unt.edu/ark:/67531/metadc1101687/m2/1/high_res_d/5905644.pdf] | * [https://digital.library.unt.edu/ark:/67531/metadc1101687/m2/1/high_res_d/5905644.pdf https://digital.library.unt.edu/ark:/67531/metadc1101687/m2/1/high_res_d/5905644.pdf] | ||
− | * [https://www.osti.gov | + | * [https://www.osti.gov/servlets/purl/5905644 https://www.osti.gov/servlets/purl/5905644], |
+ | : [https://academic.microsoft.com/#/detail/1980462798 https://academic.microsoft.com/#/detail/1980462798] |
preliminary study of the feasibility of using existing drinking water supply systems to provide hot water for heating purposes to a typical 140-home subdivision has been undertaken. This preliminary study has centered on (i) types of municipal water system designs and effects of system design upon heating use; (ii) methods of using low-to-moderate temperature water for heating purposes and possible institutional barriers; (iii) identification and description of a typical residential community suitable for hot water heating; (iv) evaluation of thermal losses in the uninsulated main distribution system from the main pumping station having assumed geothermal heating to the subdivision; (v) evaluation of thermal losses in the uninsulated street mains in the subdivision; (vi) estimation of size and cost of the pumping station main heat exchanger to supply geothermal energy to the drinking water; (vii) sizing of individual house heat exchangers; (viii) pumping and power requirements to supply the increased water flow rate through the subdivision street water distribution lines; and (ix) pumping and piping requirements to provide heating water flow from the street lines to a typical residence. From the results obtained thus far, it would appear that the use of existing uninsulated water supply systems will be advantageous more » in many communities having nearby low-to-moderate temperature geothermal resources. « le
The different versions of the original document can be found in:
Published on 01/01/1979
Volume 1979, 1979
DOI: 10.2172/5905644
Licence: CC BY-NC-SA license
Are you one of the authors of this document?