(Created page with " == Abstract == This annual progress report describes the second year's technical progress in a three-year program. This report summarizes what is known about internal flows...") |
m (Scipediacontent moved page Draft Content 749450233 to Siebenaler et al 2005a) |
(No difference)
|
This annual progress report describes the second year's technical progress in a three-year program. This report summarizes what is known about internal flows as surge precursors in centrifugal compressors and focuses on accessing factors that affect pre-surge detection. An attempt is made in this analysis to identify and quantify factors concerning compressor design and operations that affect the detection of pre-surge conditions. This progress report presents results from recent laboratory tests conducted during the course of this second year. This project is co-funded by the Gas Machinery Research Council (GMRC) and by Siemens Energy and Automation (Siemens). The most recently available measured pre-surge internal flow data is parameterized to help identify factors that affect the indications that a compressor is approaching surge. Theoretical arguments are applied to access the factors that influence surge precursors and surge initiation in different centrifugal compressors. This work is considered a step in accessing the factors that affect the success or limitations of pre-surge detection in natural gas pipeline compressors.
The different versions of the original document can be found in:
Published on 01/01/2005
Volume 2005, 2005
DOI: 10.2172/840271
Licence: CC BY-NC-SA license
Are you one of the authors of this document?